University of Ottawa finds harmonic correlations are classical, not quantum

Researchers at the Joint Attosecond Science Laboratory (JASLab) at the University of Ottawa and National Research Council of Canada have demonstrated that strong harmonic correlations observed in high harmonic generation are not necessarily evidence of quantum behavior. The team found that these correlations, previously suggested to originate from quantum effects, can instead be explained by classical fluctuations within the driving field.

Using bright squeezed vacuum sources, the researchers observed both auto- and cross-correlations in the harmonic spectrum, but showed these correlations adhere to the Cauchy-Schwarz inequality, a principle governing classical systems. A visible scaling of the measured correlation function with mean harmonic flux was also observed and successfully modeled suggesting the observed correlations are partially attributable to the limitations of the detection equipment itself.

Bright Squeezed Vacuum Enhances Harmonic Generation Yield

This finding reframes interpretations of experiments reporting nonclassical correlations in high harmonic generation, suggesting that the observed behavior may not necessarily stem from quantum mechanical properties of the light source. The team’s work highlights the importance of carefully accounting for detector characteristics when interpreting quantum light experiments, as detector response can introduce correlations that mimic quantum effects. This level of detail regarding the influence of detection equipment on experimental results is unusual and provides a more subtle understanding of the observed phenomena.

The investigation focused on comparing harmonic generation driven by both classical light and bright squeezed vacuum, a type of quantum light characterized by large photon-number fluctuations. These fluctuations were expected to enhance harmonic generation, potentially leading to higher harmonic yield and cutoff energy.

The bright squeezed vacuum did enhance harmonic generation, and the resulting correlations in the harmonic spectrum were found to be consistent with classical fluctuations originating from the driving field. The researchers distinguished between high- and low-photon-number regimes, noting that in the high-photon-number regime, harmonic yield is a proxy for photon number. Further analysis involved examining the possibility of heralding, a technique where the detection of one photon triggers a measurement of another, to reveal nonclassicality.

By conditioning the detection of one harmonic (H3) on the presence of another (H5), the team calculated a g2 value, a measure of photon statistics. The results showed that while high-order sidebands perturbed with bright squeezed vacuum exhibited g2 values comparable to the source itself, strong inter-harmonic correlations and high g2 values do not automatically indicate quantum features.

In fact, the classical driver correlations remained at the classical baseline of g2 = 1, contradicting previous reports. The bright squeezed vacuum source used in the experiments employed a double BBO configuration pumped with up to 50 joules of 800 nm light, producing up to 10 nanojoules of degenerate squeezed vacuum at 1600 nm. This source was focused into a thin-film silicon sample, and the power of the driver was controlled using a half-wave plate and polarizer pair.

The team’s meticulous characterization of the experimental setup and careful analysis of the data have provided a compelling argument against the interpretation of observed harmonic correlations as evidence of quantum behavior. This work highlights the need for rigorous analysis and careful consideration of experimental limitations when investigating quantum phenomena in high harmonic generation.

Classical and Quantum Drivers Compared in Harmonic Experiments

Recent experiments revealed that harmonic correlations, previously considered potential indicators of quantum behaviour, do not necessarily originate from quantum processes. The team’s findings suggest these correlations can arise from fluctuations inherent in the driving field itself, rather than from fundamental quantum properties of the harmonic generation process. The investigation focused on comparing harmonics generated by BSV with those produced by a classical driver, carefully matching the mean harmonic flux between the two setups.

High-order sidebands perturbed with BSV exhibited a g2 value comparable to that of the BSV itself, indicating a direct mapping of fluctuations from the linear perturbation. This directly contradicts previous reports suggesting that classically-driven harmonics could exhibit nonclassical auto- and cross-correlations in the low-photon-number regime.

The bandwidth and energy differences between the BSV and classical drivers did not account for the observed correlation differences. The team matched the mean flux of the harmonics, not the flux of the pump, to ensure a fair comparison. A visible scaling of the measured correlation function with mean harmonic flux was observed, which is well-explained by a click detector-response model.

This work emphasises the importance of rigorous analysis when interpreting experimental results in strong-field physics. The findings emphasize that attributing quantum behaviour solely based on observed harmonic correlations requires careful scrutiny and consideration of potential classical explanations.

Cauchy-Schwarz Inequality Tests Reveal Classical Harmonic Correlations

The team’s application of the Cauchy-Schwarz inequality to harmonic generation revealed no violation of the classical bound for the measured correlations, challenging earlier interpretations of similar experiments. The team’s careful modeling demonstrates that the observed signal is not necessarily indicative of non-classical light. The team’s analysis extended to heralded measurements, where the detection of one harmonic order is conditioned on the measurement of another.

While heralding significantly reduced the observed bunching of photons, the resulting correlation function, g2, remained at or above 1, indicating that the harmonics were not correlated below the shot noise limit. “The heralded g2 approximates the classical case 1), but never decreases below 1, which is consistent with the classical nature of the inter-harmonic correlations,” the researchers write.

This result contrasts with previous reports of sub-Poissonian photon-number statistics in heralded harmonics, further supporting a classical interpretation. For classically-driven harmonics, the Cauchy-Schwarz ratio, C, remained exactly at the classical boundary, while for BSV-driven harmonics, the ratio fell below 1, indicating compatibility with a classical description. The team used the Cauchy-Schwarz ratio, defined as C = (g_(ij)^(2))^2/g_(ii)^(2)g_(jj)^(2), as a probe of correlation origin.

The researchers emphasize that with comparable driving wavelengths and intensities, they found no increase in harmonic correlations with decreased driver intensity, nor any nonclassical features in the Cauchy-Schwarz or heralded measurements. “While this could be due to a number of other differences, our measurement shows that the previously reported nonclassical features appear sensitive to experimental conditions and might not be a universal feature of low-photon-number solid-state HHG,” they state.

Harmonic Flux Scaling Reveals Detector Response Influence

The team probed the auto- and cross-correlation of harmonics 3 and 5, examining how these correlations changed with varying harmonic flux. While BSV-driven harmonics exhibited super-bunching, a characteristic where g2 exceeds 2, in the low-photon-number regime, the observed scaling of these correlations was not solely attributable to the BSV source’s properties. Computational investigations revealed that the detector’s response to super-Poissonian light, specifically its on/off characteristics, could largely explain the observed modulation of the statistics.

The modeled g2 scaling closely matched experimental data, showing a three-fold reduction in g2 and suggesting the detector response is a dominant factor. This effect is substantial even at very low mean count rates, with a triple click probability less than 0.1%, and occurs while the underlying light source statistics remain constant.

Therefore, the researchers emphasize that careful consideration of detector response is key when interpreting photon-number-dependent correlations of highly bunched fields. The study computationally investigated the impact of the click detector on the measured correlations of a super-Poissonian state of light, calculating probabilities of empty, single and double events for incoming photon numbers. These calculations, combined with a modeled photon-number distribution of a perturbative third harmonic generated by a BSV with g2 = 2.3, provided a strong basis for the detector-response explanation.

The findings challenge interpretations attributing non-classical behavior solely on observed harmonic correlations, as the Cauchy-Schwarz inequality holds for both classically- and BSV-driven harmonics. The team found that the observed inter-harmonic correlations are compatible with a classical description, and that the scaling is likely due to the use of on/off detectors to measure strongly bunched statistics.

This is a significant result, as it demonstrates that seemingly quantum-like behavior can emerge from classical fluctuations combined with detector artifacts. The work highlights that measurement with multiplexed on/off detectors of highly nonlinear processes, which result in super-bunched light, can present with erroneous modulation of the statistics. While classically-driven harmonics exhibited second-order correlations consistent with unity, the BSV-driven case resulted in large harmonic fluctuations and measured super-bunching.

Nonclassicality Criteria Fail for Both Drivers in Low-Photon Regimes

Measurements of harmonic correlations, conducted with both classical and bright squeezed vacuum (BSV) drivers, reveal no violation of established nonclassicality criteria in the low-photon-number regime. The study distinguished between high- and low-photon-number regimes, extracting photon statistics from multiplexed single-photon-counting measurements when individual detection events were recorded. While BSV-driven harmonics exhibited super-bunching, a g2 greater than 2, across the measurement range, the Cauchy-Schwarz inequality remained unbroken for the measured inter-harmonic correlations.

The team observed that heralding, a technique conditioning the detection of one mode on another, significantly reduced bunching, but the resulting g2 value never fell below 1. The experimental setup employed a Ti:Sapphire laser system, generating both the classical driver and the BSV source.

This meticulous control over the input conditions was key for isolating the effects of the driver on the observed harmonic correlations. The team found that while the single-event rate between the BSV and classical drivers was approximately matched, the double-event rate, the probability of photons arriving in pairs, was orders of magnitude higher for BSV-driven harmonics. This difference is formally quantified by the second-order coherence function, g2, measured using paired photomultiplier tubes (PMTs) performing intensity correlation measurements.

However, the observed photon-number scaling of the correlation function could be closely replicated by modeling the detector effect, highlighting a limitation of using on/off detectors to characterize strongly superbunched light from highly nonlinear processes. The researchers found that when conditioning the measurement of one order on the measurement of another spectrally distinct order, the resulting heralded state exhibited sub-Poissonian photon-number statistics, another sign of nonclassicality.

Results, as shown in the study, demonstrated that the measured inter-harmonic correlations did not violate the nonclassicality criteria tested. The work acknowledges contributions from David Crane and Ryan Kroeker for technical support, as well as Dr Philip Bustard and Dr Frédéric Bouchard for productive scientific discussions, highlighting the collaborative nature of the research.

👉 More information
🗞 photon number correlations in harmonics driven with classical and quantum light
✍️ Katarzyna M. Kowalczyk, Michael T. Weil, Kevin Murzyn, André Staudte, Jeff S. Lundeen, David M. Villeneuve and Giulio Vampa
🧠 ArXiv: https://arxiv.org/html/2611.28498v1

Stay current

See today’s quantum computing news on Quantum Zeitgeist for the latest breakthroughs in qubits, hardware, algorithms, and industry deals.

Avatar of Dr. Donovan

Latest Posts by Dr. Donovan: