Three-qubit NMR processor shows compilation affects accuracy

Researchers at Universidad CEU Cardenal Herrera and Shenzhen SpinQ Technology Co., Ltd. have demonstrated that logically equivalent quantum circuit compilations do not always yield identical results on physical hardware. The team investigated a three-qubit liquid-state NMR processor using the Grover-Rudolph construction, finding that two Gray-code realisations of a level-2 uniformly controlled rotation, despite implementing the same transformation with the same angles, performed differently.

Across 700 experimental runs targeting seven distinct states, the performance contrast between these compilations was statistically significant for three targets, revealing a non-trivial sensitivity to compilation choices. The work characterizes what accuracy costs arise once a circuit reaches hardware, even when ideal models predict indistinguishability.

Grover-Rudolph Loading with R_y,X,CNOT on NMR Processors

This finding challenges the assumption that logically equivalent circuit compilations will produce identical outcomes, a critical consideration as quantum systems scale. The research team focused on the accuracy of probability-distribution loading, investigating how this metric varied depending on the chosen compilation. The advantage did not consistently favor one compilation over the other, indicating a non-trivial, target-dependent sensitivity to compilation choices. Run-level data and code are deposited for every campaign run on their own unit. The pulse-level campaign on the manufacturer’s unit is reported from summary tables, as stated there.

Removing identity-equivalent gates from the circuit, altering only the execution schedule without changing the underlying unitary, had a substantial impact on the A/B performance contrast. Specifically, this intervention resulted in a +0.0625 change (95% confidence interval [+0.0306, +0.0944], paired p =, effectively reversing which compilation performed better. The study asks what the specification of a state-preparation routine leaves undetermined once the circuit reaches hardware, and measures what it costs.

Compilation Impacts Accuracy of Probability Distribution Loading

The accuracy of state preparation on quantum hardware is demonstrably affected by choices made during circuit compilation, even when those choices do not alter the underlying unitary transformation. Two further campaigns isolate the effect within one unit. The investigation revealed that the choice of Gray-code order for the final uniformly controlled rotation, a decision that does not change the implemented operator, can measurably affect the accuracy of the probability distribution loading.

Gray-Code Realizations Show Contrast Across NMR Targets

This alteration of the execution schedule, while preserving the underlying unitary transformation, effectively reversed which compilation performed better. However, not all compilation choices exert a measurable impact; modifying the representation of inverse rotations from -θ to 720∘-θ, while maintaining the gate list, resulted in a mean fidelity shift of only -0. 0006 ( [-0. 0157, +0. 0146]) on one target during a single session.

The team emphasizes that the experiments establish that logically equivalent compilations are not experimentally equivalent, and that the observed contrast is not a result of minor discrepancies in the ideal model, where the two ladders agree to 1. 1× 10–16. “The suite cannot say which property of a target makes the difference appear, because target is aliased with session,” the authors state, highlighting a limitation of the current study.

Identity-Equivalent Gate Removal Alters Compilation Performance

Despite the absence of a linked shift in ladder contrast, a single compilation adjustment did demonstrably affect fidelity. This subtle alteration emphasises that even seemingly minor adjustments to circuit representation can introduce measurable variations in outcomes. The researchers qualified this null result, noting the comparison is confounded by a compilation difference. These values, derived from 700 experimental runs, indicate a non-uniform distribution of errors within the system.

The observed redistribution of structure, rather than simple damping, suggests that the impact of compilation choices extends beyond merely reducing overall error rates. “Structure is redistributed, not merely damped,” the authors state, emphasizing the subtle nature of these effects and the need for detailed characterization of error sources.

An attempt to isolate the source of performance differences between logically equivalent quantum compilations revealed minimal impact from altering the inverse rotations themselves. However, further investigation focused on the pulse layer itself, exploring whether variations in the timing of executed pulses could explain the observed discrepancies.

Three-Qubit NMR Processor Experimental Setup

The SpinQ Triangulum, a three-qubit room-temperature liquid-state NMR processor, formed the basis of experiments exploring how circuit compilation impacts quantum accuracy. Two Gray-code realisations of the level-2 uniformly controlled rotation, An and B, differ only in the order of their CNOT controls. Results indicated that the choice of compilation can significantly affect the observed probability distribution, suggesting that the hardware implementation introduces sensitivities not captured by theoretical models.

Across five acquisitions of this one logical circuit the contrast runs from +0.0395 to -0.0229. This finding, as the authors state, is a statement about the devices rather than the mathematics underpinning them. The team acknowledges the difficulty in directly observing the delivered pulse, noting that a longer pulse duration would also affect execution times.

Correlated Calibration State Impacts Fidelity Measurements

Absolute fidelity measurements are not universally transferable between quantum processors; comparisons focus on effects, not absolute values. This nuance arises from on-demand calibration, where devices are recalibrated based on observed performance, creating a correlation between calibration state and measured fidelity. The results demonstrate that even subtle variations in compilation can influence quantum outcomes.

👉 More information
🗞 Experimental characterisation of compilation-dependent Grover–Rudolph probability distribution loading on a three-qubit NMR processor
✍️ Antonio Falcó, Daniela Falcó-Pomares, Juan-Carlos Latorre and Yuefeng Lin
🧠 ArXiv: https://arxiv.org/html/2611.34433v1

Stay current

See today’s quantum computing news on Quantum Zeitgeist for the latest breakthroughs in qubits, hardware, algorithms, and industry deals.

Avatar of Dr. Donovan

Latest Posts by Dr. Donovan: